Mechanical vapor recompression

Mechanical vapor recompression (MVR) is an energy recovery process which can be used to recycle waste heat to improve efficiency.[1][2] Typically, the compressed vapor is fed back to help heat the mother liquor in order to produce more vapor or steam.

Applications

edit

Current

edit

Mechanical vapor recompression is used chiefly in industrial processes such as evaporation and distillation. Heat from the condenser, which would otherwise be lost, can be recovered and used in the evaporation process.

Past

edit

MVR was successfully tested in a locomotive under the name of "The Anderson System".[3][4] Testing found that it almost completely eliminated steam ejection, as well as greatly reduced operating noise. An Harold Holcroft, organiser of the tests wrote the following:

"In the ordinary way this would have created much noise and clouds of steam, but with the condensing set in action it was all absorbed with the ease with which snow would melt in a furnace! The engine was as silent as an electric locomotive and the only faint noises were due to slight pounding of the rods and a small blow at a piston gland. This had to be experienced to be believed; but for the regulator being wide open and the reverser well over, one would have imagined that the second engine (an LSWR T14 class that had been provided as a back-up) was propelling the first".[5]

The trials continued until 1934 but various problems arose, mostly with the fan for forced draught, and the project went no further.[3] The locomotive was converted back to standard form in 1935.[6]

MVR was also used in the Cristiani compressed steam system for locomotive transmission. Although it was technically feasible, it failed to become popular because of its complexity.[7]

Benefits

edit

The main benefit of MVR mechanical vapour recompression is that it allows for significant energy savings.

  • Lower energy requirement
  • Lower operating cost
  • Very small capacity of Boiler or No Boiler
  • No cooling water required
  • Usually 1 or 2 effect which will simplify operation
  • More than 97% of recovered Water can be recycled to process
  • Smaller footprint
  • Lower carbon footprint

Alternatives

edit

Alternatives to mechanical vapor recompression (MVR) are:

A combination of the three methods may be used depending on the process. For instance, a 3-effect evaporator circuit may be installed using MVR to transfer heat.

References

edit
  1. ^ "Use Vapor Recompression to Recover Low-Pressure Waste Steam" (PDF). energy.gov. Retrieved 1 August 2023.
  2. ^ "Steam Compression". www.spilling.de. Retrieved 1 August 2023.
  3. ^ a b Holcroft, Harold (1965). "XIII Interlude: A New Horizon, 1927 et seq.". Locomotive Adventure: Fifty Years With Steam. Ian Allan. pp. 155–173.
  4. ^ Holcroft (1965), pp. 207–209, Appendix V, Surbiton Power Station: Short Test of Fuel-Saving 7–8 January 1932.
  5. ^ Robertson, Kevin, Leader and Southern Experimental Steam, Alan Sutton Publishing 1990, pp 22-33, ISBN 0-86299-743-7
  6. ^ Douglas Self (2008-04-01). "The Holcroft-Anderson Recompression Locomotive". Retrieved 2012-02-12.
  7. ^ "The Cristiani Compressed Steam System".