A duochrome test is a test commonly used to refine the final sphere in refraction (undercorrection and overcorrection), which makes use of the longitudinal chromatic aberration of the eye. Because of the chromatic aberration of the eye, the shorter wavelengths (green) are focused in front of the longer red wavelengths. It is assumed that best vision is attained when the yellow wavelengths are focused on the retina.[1]

Testing

edit

The patient is asked to compare the clarity of the letters on the green and the red side. If the letters of the green side are clearer +0.25 D sphere is added and if the letters on the red side are clearer -0.25 D sphere is added. With optimal spherical correction, the letters on the red and green halves of the chart appear equally clear.

Because this test is based on chromatic aberration and not on color discrimination, it is used even with people having color vision deficiency.[2]

The eye with overactive accommodation may still require too much minus sphere in order to balance the red and green. Cycloplegia may be necessary.

The duochrome test is not used with patients whose visual acuity is worse than 20/30 (6/9), because the 0.50 D difference between the two sides is too small to distinguish.

See also

edit

References

edit
  1. ^ Gantz, Liat; Schrader, Shlomo; Ruben, Ruthie; Zivotofsky, Ari Z. (2015-03-16). "Can the Red-Green Duochrome Test Be Used Prior to Correcting the Refractive Cylinder Component?". PLOS ONE. 10 (3): e0118874. doi:10.1371/journal.pone.0118874. ISSN 1932-6203. PMC 4361575. PMID 25775478.
  2. ^ Makgaba, Nkalebetja T.; Mathebula, Solani D. (2020-09-30). "Investigation of the unfused cross cylinder test as an alternative method for the determination of spherical distance refraction end points". African Vision and Eye Health. 79 (1). doi:10.4102/aveh.v79i1.514. ISSN 2410-1516. S2CID 224991918.