Indentation hardness tests are used in mechanical engineering to determine the hardness of a material to deformation. Several such tests exist, wherein the examined material is indented until an impression is formed; these tests can be performed on a macroscopic or microscopic scale.

When testing metals, indentation hardness correlates roughly linearly with tensile strength,[1] but it is an imperfect correlation often limited to small ranges of strength and hardness for each indentation geometry. This relation permits economically important nondestructive testing of bulk metal deliveries with lightweight, even portable equipment, such as hand-held Rockwell hardness testers.

Material hardness

edit

Different techniques are used to quantify material characteristics at smaller scales. Measuring mechanical properties for materials, for instance, of thin films, cannot be done using conventional uniaxial tensile testing. As a result, techniques testing material "hardness" by indenting a material with a very small impression have been developed to attempt to estimate these properties.

Hardness measurements quantify the resistance of a material to plastic deformation. Indentation hardness tests compose the majority of processes used to determine material hardness, and can be divided into three classes: macro, micro and nanoindentation tests.[2][3] Microindentation tests typically have forces less than 2 N (0.45 lbf). Hardness, however, cannot be considered to be a fundamental material property.[citation needed] Classical hardness testing usually creates a number which can be used to provide a relative idea of material properties.[3] As such, hardness can only offer a comparative idea of the material's resistance to plastic deformation since different hardness techniques have different scales.

The equation based definition of hardness is the pressure applied over the contact area between the indenter and the material being tested. As a result hardness values are typically reported in units of pressure, although this is only a "true" pressure if the indenter and surface interface is perfectly flat.[citation needed]

Instrumented indentation

edit
 
Instrumented Indentation Tester

Instrumented indentation basically indents a sharp tip into the surface of a material to obtain a force-displacement curve. The results provide a lot of information about the mechanical behavior of the material, including hardness, e.g., elastic moduli and plastic deformation. One key factor of instrumented indentation test is that the tip needs to be controlled by force or displacement that can be measured simultaneously throughout the indentation cycle.[4] Current technology can realize accurate force control in a wide range. Therefore hardness can be characterized at many different length scales, from hard materials like ceramics to soft materials like polymers.

The earliest work was finished by Bulychev, Alekhin, Shorshorov in the 1970s, who determined that Young's modulus of a material can be determined from the slope of a force vs. displacement indentation curve as:[5]

 
 : material stiffness, which is the slope of the curve
 : the tip-sample contact area
 : reduced modulus, defined as:
 

Where   and   are the Young's modulus and Poisson's ratio of the sample, an   and   are that of the indenter. Since typically,  , the second term can typically be ignored.

The most critical information, hardness, can be calculated by:

 

Commonly used indentation techniques, as well as detailed calculation of each different method, are discussed as follows.

Macroindentation tests

edit

The term "macroindentation" is applied to tests with a larger test load, such as 1 kgf or more. There are various macroindentation tests, including:

There is, in general, no simple relationship between the results of different hardness tests. Though there are practical conversion tables for hard steels, for example, some materials show qualitatively different behaviors under the various measurement methods. The Vickers and Brinell hardness scales correlate well over a wide range, however, with Brinell only producing overestimated values at high loads.

Indentation procedures can, however, be used to extract genuine stress-strain relationships. Certain criteria need to be met if reliable results are to be obtained. These include the need to deform a relatively large volume, and hence to use large loads. The methodologies involved are often grouped under the term Indentation plastometry, which is described in a separate article.

Microindentation tests

edit

The term "microhardness" has been widely employed in the literature to describe the hardness testing of materials with low applied loads. A more precise term is "microindentation hardness testing." In microindentation hardness testing, a diamond indenter of specific geometry is impressed into the surface of the test specimen using a known applied force (commonly called a "load" or "test load") of 1 to 1000 gf. Microindentation tests typically have forces of 2 N (roughly 200 gf) and produce indentations of about 50 μm. Due to their specificity, microhardness testing can be used to observe changes in hardness on the microscopic scale. Unfortunately, it is difficult to standardize microhardness measurements; it has been found that the microhardness of almost any material is higher than its macrohardness. Additionally, microhardness values vary with load and work-hardening effects of materials.[3] The two most commonly used microhardness tests are tests that also can be applied with heavier loads as macroindentation tests:

In microindentation testing, the hardness number is based on measurements made of the indent formed in the surface of the test specimen. The hardness number is based on the applied force divided by the surface area of the indent itself, giving hardness units in kgf/mm2. Microindentation hardness testing can be done using Vickers as well as Knoop indenters. For the Vickers test, both the diagonals are measured and the average value is used to compute the Vickers pyramid number. In the Knoop test, only the longer diagonal is measured, and the Knoop hardness is calculated based on the projected area of the indent divided by the applied force, also giving test units in kgf/mm2.

The Vickers microindentation test is carried out in a similar manner welling to the Vickers macroindentation tests, using the same pyramid. The Knoop test uses an elongated pyramid to indent material samples. This elongated pyramid creates a shallow impression, which is beneficial for measuring the hardness of brittle materials or thin components. Both the Knoop and Vickers indenters require polishing of the surface to achieve accurate results.[citation needed]

Scratch tests at low loads, such as the Bierbaum microcharacter test, performed with either 3 gf or 9 gf loads, preceded the development of microhardness testers using traditional indenters. In 1925, Smith and Sandland of the UK developed an indentation test that employed a square-based pyramidal indenter made from diamond.[11] They chose the pyramidal shape with an angle of 136° between opposite faces in order to obtain hardness numbers that would be as close as possible to Brinell hardness numbers for the specimen. The Vickers test has a great advantage of using one hardness scale to test all materials. The first reference to the Vickers indenter with low loads was made in the annual report of the National Physical Laboratory in 1932. Lips and Sack describes the first Vickers tester using low loads in 1936.[citation needed]

There is some disagreement in the literature regarding the load range applicable to microhardness testing. ASTM Specification E384, for example, states that the load range for microhardness testing is 1 to 1000 gf. For loads of 1 kgf and below, the Vickers hardness (HV) is calculated with an equation, wherein load (L) is in grams force and the mean of two diagonals (d) is in millimeters:

 

For any given load, the hardness increases rapidly at low diagonal lengths, with the effect becoming more pronounced as the load decreases. Thus at low loads, small measurement errors will produce large hardness deviations. Thus one should always use the highest possible load in any test. Also, in the vertical portion of the curves, small measurement errors will produce large hardness deviations.

Nanoindentation tests

edit

Sources of error

edit

The main sources of error with indentation tests are poor technique, poor calibration of the equipment, and the strain hardening effect of the process. However, it has been experimentally determined through "strainless hardness tests" that the effect is minimal with smaller indentations.[12]

Surface finish of the part and the indenter do not have an effect on the hardness measurement, as long as the indentation is large compared to the surface roughness. This proves to be useful when measuring the hardness of practical surfaces. It also is helpful when leaving a shallow indentation, because a finely etched indenter leaves a much easier to read indentation than a smooth indenter.[13]

The indentation that is left after the indenter and load are removed is known to "recover", or spring back slightly. This effect is properly known as shallowing. For spherical indenters the indentation is known to stay symmetrical and spherical, but with a larger radius. For very hard materials the radius can be three times as large as the indenter's radius. This effect is attributed to the release of elastic stresses. Because of this effect the diameter and depth of the indentation do contain errors. The error from the change in diameter is known to be only a few percent, with the error for the depth being greater.[14]

Another effect the load has on the indentation is the piling-up or sinking-in of the surrounding material. If the metal is work hardened it has a tendency to pile up and form a "crater". If the metal is annealed it will sink in around the indentation. Both of these effects add to the error of the hardness measurement.[15]

Relation to yield stress

edit

When hardness,  , is defined as the mean contact pressure (load/ projected contact area), the yield stress,  , of many materials is proportional to the hardness by a constant known as the constrain factor, C.[16]

 

where:

 

The hardness differs from the uni-axial compressive yield stress of the material because different compressive failure modes apply. A uni-axial test only constrains the material in one dimension, which allows the material to fail as a result of shear. Indentation hardness on the other hand is constrained in three dimensions which prevent shear from dominating the failure.[16]

See also

edit

References

edit
  1. ^ Pavlina, E.J.; Van Tyne, C.J. (2008). "Correlation of Yield Strength and Tensile Strength with Hardness for Steels". Journal of Materials Engineering and Performance. 17 (6): 888–893. Bibcode:2008JMEP...17..888P. doi:10.1007/s11665-008-9225-5. S2CID 135890256.
  2. ^ Broitman, Esteban (March 2017). "Indentation Hardness Measurements at Macro-, Micro-, and Nanoscale: A Critical Overview". Tribology Letters. 65 (1): 23. doi:10.1007/s11249-016-0805-5. ISSN 1023-8883.
  3. ^ a b c Meyers and Chawla (1999): "Mechanical Behavior of Materials", 162–168.
  4. ^ Oliver, W.C.; Pharr, G.M. (June 1992). "An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments". Journal of Materials Research. 7 (6): 1564–1583. Bibcode:1992JMatR...7.1564O. doi:10.1557/JMR.1992.1564. ISSN 0884-2914. S2CID 137098960.
  5. ^ Shnyrev, G.D., Bulychev, S.I. & Alekhin, V.P. & Shorshorov, M.K. & Ternovskii, A.P. (1975). "Determining Young's modulus from the indentor penetration diagram". Zavodskaya Laboratoriya. 41 (9): 1137–1140.{{cite journal}}: CS1 maint: multiple names: authors list (link)
  6. ^ EBP Vickers hardness test http://www.hiebp.com
  7. ^ EBP Brinell hardness test http://www.hiebp.com
  8. ^ EBP Knoop hardness test http://www.hiebp.com
  9. ^ EBP Rockwell hardness test http://www.hiebp.com
  10. ^ EBP Shore hardness test http://www.hiebp.com
  11. ^ R.L. Smith and G.E. Sandland, "An Accurate Method of Determining the Hardness of Metals, with Particular Reference to Those of a High Degree of Hardness," Proceedings of the Institution of Mechanical Engineers, Vol. I, 1922, p 623–641.
  12. ^ Tabor, p. 16.
  13. ^ Tabor, p. 14.
  14. ^ Tabor, pp. 14-15.
  15. ^ Tabor, p. 15.
  16. ^ a b Fischer-Cripps, Anthony C. (2007). Introduction to contact mechanics (2nd ed.). New York: Springer. pp. 156–157. ISBN 978-0-387-68188-7. OCLC 187014877.
edit

Bibliography

edit